HANNA HI9813-6 Waterproof Portable pH/EC/TDS/Temperature Meter with CAL CHECK™
- Brand: Hanna Instruments
- Product Code: HI9813-6
- Availability: 10 - 14 Working Days
- Rp.8,900,000
Tags: HANNA, pH, Conductivity, TDS, Turbidity, Dissolved Oxygen, Tester
The HI9813-6 portable meter features a large LCD which displays either pH, EC, TDS or temperature readings along with tutorial instructions.. The pH readings are displayed with a 0.1 resolution and an accuracy of +/-0.1 pH while the EC and TDS readings are displayed with a 0.01 mS/cm and 1 ppm (mg/L) resolution and 2% full scale accuracy. The EC range of the HI9813-6 is from 0.00 to 4.00 mS/cm and TDS is from 0 to 1999 ppm. The temperature correction coefficient (β) is fixed at 2 %/oC and allows for automatic temperature compensated measurements of EC and TDS. The HI9813-6 is a basic pH/EC/TDS meter that is calibrated manually to a single point with the use of two trimmers. pH is calibrated to pH 7.01 while EC/TDS is calibrated to either 1.41 mS/cm (1413 µS/cm) or 1500 ppm. The LCD screen has battery life indicator as well as on-screen tutorial messages. The supplied HI1285-6 probe is a polypropylene body, amplified pH electrode with a built-in EC/TDS and temperature sensors. The amplifier for the pH electrode prevents interference from humidity and electrical noise from common sources including from motors, ballasts or pumps. The HI9813-6 is a versatile meter for the agriculture, greenhouse and hydroponics industries.
The HI9813-6 meter also offers the CAL Check™ feature that alerts the user to a problem with a pH electrode. This feature is important for customers that calibrate only to pH 7.0; if there is a fracture on the pH glass of the electrode, the pH meter will always display pH 7.0 regardless of the solution being measured. This can be disastrous for the person that calibrates at pH 7.0 and takes readings of samples with an expected pH of 7.0. The user will never be aware that there is a problem with the electrode. This can result in inaccurate pH measurements, which for a greenhouse can affect the growth of the plants. Placing the HI1285-6 pH/EC electrode in the HI50021 CAL Check™ solution helps users determine if the probe needs to be calibrated, cleaned or replaced. When the probe is placed in solution the user presses the “Check” key. The meter runs CAL Check™ diagnostics and will display either “Probe is OK” or “Clean Probe and Calibrate”. If the reading is around pH 4.0 when the probe is placed in the solution then the probe is broken and needs to be replaced.
Features:
Water resistant
Automatic Temperature Compensation for pH and conductivity
On-screen tutorial messages for calibration
Simple calibration; Dials located on the front panel makes calibration quick and simple, even for non-technical users
Exclusive CAL CHECK feature; Alerts users of calibration status
Battery % displayed on startup
BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings
Fast response multiparameter probe
Switch parameters at the touch of a button
What's in the Box:
(1) HI1285-6 multiparameter probe
(1) HI70007 pH 7.01 buffer solution sachet
(1) HI70442 1500 ppm calibration solution sachet
(1) HI70031 1413 µS/cm calibration solution sachet
(2) HI700661 electrode cleaning solution sachets
(2) HI50021 calibration check solution sachets
(1) 9V battery
(1) Instructions
(1) Rugged carrying case.