Gill Instruments MetPak Pro Base Station
- Brand: Gill Instruments
- Product Code: 1723 -2A-1-111
- Availability: 10 - 14 Working Days
- Rp.53,500,000
Tags: Gill Instruments, WS1, WindSonic, Wind Sensors, RS-232
MetPak RG is supplied complete with a tipping bucket rain gauge adding to those parameters provided by MetPak at a very attractive price, while maintaining the reference quality measurement concept. The rain gauge is included along with the base plate, 6 metres of cable and is calibrated to the MetPak ensuring excellent accuracy and data quality. The design of the MetPak RG allows all measurements to be as accurate as possible without influencing other measured parameters yet provides a complete, compact, reference quality system. The unit is especially suitable for harsh, coastal and fixed marine platforms where accuracy of the precipitation measurements is paramount and is supplied with selectable Gill ASCII, NMEA SDI-12 and Modbus outputs.
- Wind Speed & Direction
- Precipitation
- Temperature
- Barometric Pressure
- Humidity
- Dew Poin
Includes:
- (1) Gill Instruments MetPak Pro Base Station
- (1) MetSet configuration software
- (1) MetView data logging/visualisation software
- (1) Mounting kit to adapt to poles or masts
- (1) Selectable ASCII, NMEA, SDI-12 or Modbus Outputs
Specifications:
- Wind Measurement: Sensor: WindSonic ultrasonic; Parameters: Polar; Wind Speed & Direction or U & V Vectors; Wind Speed: Range:0-60m/s (134 mph)Air Temperature : Air temperature: Pt100 1/3 Class B; Range: -50°C to +100°C; Accuracy: ±0.1°C; Resolution: 0.1°C (0.1°F); Units of measure: °C or °F. Relative Humidity: Sensor: Rotronic HygroClip model HC2-S3.Compensated for temperature dependency; Range: 0-100% RH; Accuracy; ± 0.8% @23°C; Resolution;0.1% RH.;Units of measure: % RH
- Air Temperature: Air temperature: Pt100 1/3 Class B; Range: -50°C to +100°C; Accuracy: ±0.1°C; Resolution: 0.1°C (0.1°F); Units of measure; °C or °F.
- Relative Humidity: Range: 0-100% RH; Accuracy: ±0.8% @ 23°C: Resolution: 0.1% RH; Units of measure:% RH. Compensated for temperature dependency
- Barometric Range: Range: 600-1100hPa; Accuracy: ±0.5hPa; Resolution: 0.1hPa; Units of measure: hPa, mbar, mmHg, InHg. Compensated for temperature dependency -30°C to +70°C.
- DewPoint: Resolution: 0.1°C (0.1°F); Units of measure: °C or °F; Accuracy: ±0.15°C (23°C ambient temp @ 20°C dew point).
- Power Supply: Input voltage: 5 V to 30 V; Current: < 16mA (Output 1 second) @12 V; SDI-12: Input voltage: 12V nominal (9.6-16 V ); Current: < 6.5mA Low power operation
- Output: Digital outputs: RS232, RS422, RS485*, SDI-12 or Modbus (user selectable)* 2 wire point to point
Baud rates: 4800-57600 (ASCII) or 1200 (SDI-12); Protocols: ASCII, SDI-12 V 1.3, NMEA 0183, Modbus (RTU and ASCII)
Data output: 1s, 2s, 4s or polled mode. - Inputs: Analogue 1: 0-5V or 4-20mA loop or self powered;Analogue 2: 0-5V or 4-20mA loop or self powered; MetPak Pro A-D Conversion: 12 bit resolution with an accuracy of ± 0.1% of reading +35µV offset; Pt100 Temperature Probe; 4 wire Pt100 conforms to IEC 60751; Digital: Contact closure for tipping bucket rain gauge capable of capturing events up to 10Hz
- Mechanical: External construction: UV stabilised white thermoplastic; Fittings: Anodised Aluminium bracket to allow fitting to 30mm to 58mm mast dimensions; Weight: 2.1kg (including bracket).
- Software: MetView: Free software for the display of data and logging; MetSet: Free software for the configuration of the MetPak, MetPak RG & MetPak Pro.