Hach Pocket Colorimeter™ II, Chlorine (Free and Total)
- Brand: Hach
- Product Code: 5870000
- Availability: 10 - 14 Working Days
- Rp.14,600,000
Tags: HACH, Colorimeter, multiparameter, spectrophometer
The new Pocket Colorimeter™ II Filter Photometer is a true go-anywhere instrument. It's lightweight and battery operated, suitable for extended field work or quick, on-the-spot process monitoring. The instrument has two channels in which measurements can be made. Each channel will accept a user-defined calibration curve. Up to 10 standards can be used to determine the calibration. The curve is generated by a point-to-point straight line segment between each standard used. Linear and non-linear positive or negative slope calibrations can be performed. A calibration curve may also be manually entered from the keypad if a previously determined curve has been made on the Colorimeter. At least two data pairs (concentration and absorbance) are required.
Includes:
- (1) Hach Chlorine pocket colorimeter II
- (1) Reagent set with 100 tests each (low range) or 50 tests each (high range)
- (6) Sample cells
- (1) Carrying case
- (1) Operations manual
Specifications:
- Absorbance: 0 - 2.5 Abs
- Battery Life: 2000 tests* backlight will decrease battery life
- Battery Requirements: 4, AAA size alkali cells
- Compliance Certifications: European CE mark
- Data Logger: 10 measured values + time
- Dimensions (H x W x D): 155 mm x 61 mm x 35 mm
- Display: LCD, backlit
- Enclosure Rating: IP67 (excludes battery compartment)
- EPA compliant: Yes
- Includes: PC II, sample cells, manual, carry case. Reagents included: 100 tests each for low range or 50 tests each for high range.
- Instrument: Kit includes PC II
- Interface: rubber keys
- Method: 8021 (F),
- 8167 (T)
- Method Name: Colorimeter/DPD
- Number of tests: 50 - 100
- Operating Humidity: max. 90 % relative humidity (non-condensing)
- Operating Mode: Hach vial tests for water analysis
- Operating Temperature: 10 to 40 °C
- Parameter: Chlorine, low range - as free & total Cl2
- Photometric Measuring Range: 0 to 2 Abs
- Power supply: 4, AAA size alkaline cells
- Range: to F&T Cl2
- Range 2: 0.1 to 8.0 mg/L CI₂
- Sample Cell Compatibility: 1 inch round / 13 mm round /1cm square (with optional adapter)
- Sample Cell Path Length: 1 inch round (25,4 mm) and 10mm square with adapter
- Smallest Increment Steps: 0.01;0.1
- Spectral Bandwidth: 15 nm filter bandwidth
- User Interface: Numeric
- Warranty: 2 years
- Wavelength: Fixed wavelength varies with model
- Wavelength Accuracy: Fixed wavelength ± 2 nm varies with model
- Wavelength Range: varies with model
- Wavelength Selection: Fixed wavelength
- Weight: 0.51 lbs. (0.23 kg)